Data Report
Alert /
Contributed by BGS
Return-Path:
X-Original-To: seismo@isc.ac.uk
Delivered-To: seismo@isc.ac.uk
Received: from EUR01-DB5-obe.outbound.protection.outlook.com (mail-db5eur01on0099.outbound.protection.outlook.com [104.47.2.99])
by www.gxjydl.com (Postfix) with ESMTP id 2B444613D8
for ; Mon, 20 Feb 2017 14:21:16 +0000 (GMT)
Dkim-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=nercacuk.onmicrosoft.com; s=selector1-bgs-ac-uk;
h=From:Date:Subject:Message-ID:Content-Type:MIME-Version;
bh=VmnRgMr7B0GaNeAPOjWxHTXqTmE3q9JZLZcRyvOiOyo=;
b=STIfzF5YX7RmAxLfBa4f2tsEzJ4xgKAcxBXRCK1hInaTmHHa5AB2BCie1zmcnEBp591IxUU0/Hvydt08JqHTKFsRA/xkTkDBtv22Nw2hMtjmdu+8m4IvT9W60J1jBQSva1CsVyUuOn2YsmMLvbZN3hc3DPwZVbHqllVatVLLiyk=
Received: from HE1PR06MB1643.eurprd06.prod.outlook.com (10.169.120.149) by
HE1PR06MB1643.eurprd06.prod.outlook.com (10.169.120.149) with Microsoft SMTP
Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_CBC_SHA384_P384) id
15.1.919.13; Mon, 20 Feb 2017 14:39:04 +0000
Received: from HE1PR06MB1643.eurprd06.prod.outlook.com ([10.169.120.149]) by
HE1PR06MB1643.eurprd06.prod.outlook.com ([10.169.120.149]) with mapi id
15.01.0919.015; Mon, 20 Feb 2017 14:39:04 +0000
The following preliminary information is available for this event:
DATE:20 February 2017
ORIGIN TIME:13:36 26.2s UTC
LAT/LONG:49.599? North / 0.664? West
GRID REF:496.5kmE / -32.6kmN
DEPTH:0 km (fixed)
MAGNITUDE:2.5 ML
LOCALITY:English Channel (approximately 115km SSE of Ventnor, Isle of Wight, England)
2017 220 1336 26.24Lf 49.599 -0.664 0.0F BGS 21 0.3 2.5LBGS 1
GAP=174 0.79 3.1 4.5 0.0 -0.9305E+01 0.0000E+00 0.0000E+00E
2017-02-20-1335-37S.Regio_334 6
ACTION:REE 17-02-20 14:16 OP:dag STATUS: ID:20170220133626 I
XNEAR 500.0 XFAR 1000.0 SDEP 15.0 3
ENGLISH CHANNEL 23
115KM SSE VENTNOR 3
STAT SP IPHASW D HRMM SECON CODA AMPLIT PERI AZIMU VELO SNR AR TRES W DIS CAZ7
JQE EZ EP 1336 45.02 38 0.2210 109 247
JDG EZ EP 1336 45.05 38 0.1410 110 246
JDC EZ EP 1336 45.03 38 0.1110 110 246
JDC EN IAML 1336 47.53 433.7 0.16 110 246
JDC EE IAML 1336 47.68 247.9 0.16 110 246
JLP EZ EP 1336 45.34 38 0.1710 112 250
JRS EZ EP 1336 45.28 38 -0.1310 113 247
JSA HZ EP 1336 46.26 38 0.0010 119 248
JSA HE IAML 1337 3.39 53.5 0.16 119 248
JSA HN IAML 1337 4.37 49.7 0.18 119 248
JVM EZ EP 1336 46.53 38 0.0910 120 250
HMNX HZ EP 1336 52.77 35 0.6910 158 26
HMNX HN IAML 1336 56.27 142.9 0.50 158 26
HMNX HE IAML 1337 19.00 135.4 0.64 158 26
WOL BZ EP 1336 57.28 30 0.3010 195 348
ELSH HZ EP 1336 59.62 30 0.1610 215 36
ELSH HN IAML 1337 30.14 29.6 0.28 215 36
ELSH HE IAML 1337 33.89 28.1 0.26 215 36
DYA HZ EP 1337 3.76 30 -0.4110 252 293
DYA HE IAML 1337 47.33 17.2 0.20 252 293
DYA HN IAML 1337 48.07 17.7 0.56 252 293
STRD HZ EP 1337 5.81 30 0.1210 264 337
STRD HN IAML 1337 56.51 48.6 0.66 264 337
STRD HE IAML 1338 2.32 34.0 0.52 264 337
MONM HZ EP 1337 9.43 30 0.3610 291 330
MONM HN IAML 1337 58.66 12.5 0.64 291 330
MONM HE IAML 1338 7.96 17.7 0.50 291 330
ELMS HZ EP 1337 9.82 30 -0.4210 301 22
ELMS HN IAML 1338 1.58 34.6 0.46 301 22
ELMS HE IAML 1338 7.46 27.0 0.48 301 22
MCH1 HZ EP 1337 11.61 30 -0.2310 313 329
MCH1 HE IAML 1337 58.53 22.9 0.56 313 329
MCH1 HN IAML 1338 3.50 18.1 0.42 313 329
HTL HZ EP 1337 12.04 30 0.2410 313 301
HTL HN IAML 1338 5.10 18.2 0.44 313 301
HTL HE IAML 1338 5.64 13.9 0.66 313 301
CCA1 HZ EP 1337 14.17 30 -0.2810 334 283
CCA1 HE IAML 1337 26.59 7.7 0.46 334 283
CCA1 HN IAML 1338 9.90 7.1 0.62 334 283
HLM1 HZ EP 1337 17.92 30 0.2110 360 335
HLM1 HE IAML 1338 19.22 8.0 0.44 360 335
HLM1 HN IAML 1338 19.76 7.3 0.76 360 335
LPW HZ EP 1337 18.61 30 -0.0610 368 321
RSBS HZ EP 1337 20.46 30 -0.8410 389 314
RSBS HN IAML 1337 38.51 4.8 0.94 389 314
RSBS HE IAML 1338 3.73 5.3 0.16 389 314
HGN BZ EP 1337 33.25 30 -0.4410 488 72
________________________________
This message (and any attachments) is for the recipient only. NERC is subject to the Freedom of Information Act 2000 and the contents of this email and any reply you make may be disclosed by NERC unless it is exempt from release under the Act. Any material supplied to NERC may be stored in an electronic records management system.