Data Report
Alert /
Contributed by BGS
Return-Path:
X-Original-To: seismo@isc.ac.uk
Delivered-To: seismo@isc.ac.uk
Received: from GBR01-LO2-obe.outbound.protection.outlook.com (mail-eopbgr100115.outbound.protection.outlook.com [40.107.10.115])
by www.gxjydl.com (Postfix) with ESMTP id EB30D61442
for ; Thu, 22 Nov 2018 13:09:52 +0000 (GMT)
Dkim-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=bgs.ac.uk;
s=selector1;
h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck;
bh=Yq8fO8fqc73JVDYxnOkTLACeJy+pY1EZAE95CGSBR+4=;
b=BnIrN9QYHRcKQYZg9uMzh3k2JEy0qhxkGY9Kr0RkI8gcZFNq+LI04hGFx5LlTIeo7YpHnCFDvvhlNR0UGLYb8d7a/eS71S5lHN+imgBy2BJM3Jw0E8ptZQPCWUTVSKbBlQ3elfgbzdWB3ifvMfu4d1j74p/vschkv00DJeRs4Gg=
Received: from LO1P123MB0068.GBRP123.PROD.OUTLOOK.COM (10.167.24.135) by
LO1P123MB1011.GBRP123.PROD.OUTLOOK.COM (10.167.26.142) with Microsoft SMTP
Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id
15.20.1294.45; Thu, 22 Nov 2018 13:09:43 +0000
Received: from LO1P123MB0068.GBRP123.PROD.OUTLOOK.COM
([fe80::446:b490:ff2f:2dd]) by LO1P123MB0068.GBRP123.PROD.OUTLOOK.COM
([fe80::446:b490:ff2f:2dd%5]) with mapi id 15.20.1361.015; Thu, 22 Nov 2018
13:09:43 +0000
The following preliminary information is available for this event:
DATE:22 November 2018
ORIGIN TIME:10:03 33.2s UTC
LAT/LONG:50.155? North / 0.980? East
GRID REF:612.8kmE / 32.7kmN
DEPTH:0 km (fixed)
MAGNITUDE:2.4 ML
LOCALITY:English Channel (approximately 110 km SE of Brighton)
2018 1122 1003 33.24Lf 50.155 0.980 0.0F BGS 16 0.5 2.4LBGS 1
GAP=155 1.21 4.6 6.3 0.0 -0.1099E+02 0.0000E+00 0.0000E+00E
2018-11-22-1002-02S.BLAC__147 6
2018-11-22-1003-30S.EXT___104 6
2018-11-22-1003-30S.EWA___308 6
ACTION:REG 18-11-22 12:40 OP:dag STATUS: ID:20181122100202 I
XNEAR 500.0 XFAR 1000.0 SDEP 0.0 3
ENGLISH CHANNEL 23
110KM SE BRIGHTON 3
STAT SP IPHASW D HRMM SECON CODA AMPLIT PERI AZIMU VELO AIN AR TRES W DIS CAZ7
HMNX HZ EP 10 3 49.27 38 0.1810 91.4 330
HMNX HN IAML 10 4 4.58 157.9 0.22 91.4 330
HMNX HE IAML 10 4 5.06 164.8 0.25 91.4 330
ELSH HZ EP 10 3 51.85 38 -0.2910 111 6
ELSH HE IAML 10 4 8.01 46.5 0.26 111 6
ELSH HN IAML 10 4 9.08 58.4 0.36 111 6
ELMS HZ EP 10 4 7.62 30 0.9910 216 0
ELMS HN IAML 10 4 37.83 66.1 0.26 216 0
ELMS HE IAML 10 4 42.19 70.2 0.60 216 0
JDG EZ EP 10 4 10.50 30 0.4510 243 245
JDG EN IAML 10 4 46.95 18.9 0.32 243 245
JDG EE IAML 10 4 50.87 12.4 0.20 243 245
JDC EZ EP 10 4 10.42 30 0.3610 243 245
JDC EE IAML 10 4 16.03 75.8 0.20 243 245
JDC EN IAML 10 4 51.21 109.8 0.18 243 245
JLP EZ EP 10 4 10.37 30 0.1610 244 247
JRS EE IAML 10 4 51.44 26.7 0.34 246 245
JRS EN IAML 10 4 54.01 21.6 0.52 246 245
UCC HZ EP 10 4 10.04 30 -0.9310 250 72
JSA HZ EP 10 4 11.40 30 0.2810 252 246
JSA HE IAML 10 4 53.03 12.9 0.30 252 246
JSA HN IAML 10 4 55.04 13.8 0.30 252 246
DOU HZ EP 10 4 12.36 30 0.3410 259 90
WACR HZ EP 10 4 15.24 30 -0.3010 287 355
WACR HN IAML 10 4 59.48 22.5 0.66 287 355
WACR HE IAML 10 4 59.76 15.7 0.35 287 355
MONM HZ EP 10 4 20.06 30 -0.2610 325 307
MONM HE IAML 10 5 10.22 8.8 0.32 325 307
MONM HN IAML 10 5 19.91 9.5 0.64 325 307
DYA HZ EP 10 4 23.30 30 -0.3310 351 277
DYA HN IAML 10 4 24.42 5.3 0.14 351 277
DYA HE IAML 10 4 34.01 8.1 0.36 351 277
HTL HZ EP 10 4 28.88 30 -0.5610 398 286
HTL HE IAML 10 4 53.68 8.5 0.72 398 286
HTL HN IAML 10 5 12.30 12.3 0.54 398 286
CCA1 HZ EP 10 4 34.38 30 -0.7510 443 273
This email and any attachments are intended solely for the use of the named recipients. If you are not the intended recipient you must not use, disclose, copy or distribute this email or any of its attachments and should notify the sender immediately and delete this email from your system.
UK Research and Innovation has taken every reasonable precaution to minimise risk of this email or any attachments containing viruses or malware but the recipient should carry out its own virus and malware checks before opening the attachments. UK Research and Innovation does not accept any liability for any losses or damages which the recipient may sustain due to presence of any viruses.
Opinions, conclusions or other information in this message and attachments that are not related directly to UK Research and Innovation business are solely those of the author and do not represent the views of UK Research and Innovation.