Data Report
Alert /
Contributed by BGS
Return-Path:
X-Original-To: seismo@isc.ac.uk
Delivered-To: seismo@isc.ac.uk
Received: from GBR01-LO2-obe.outbound.protection.outlook.com (mail-eopbgr100122.outbound.protection.outlook.com [40.107.10.122])
by www.gxjydl.com (Postfix) with ESMTP id 08263613C0
for ; Wed, 27 Feb 2019 13:29:42 +0000 (GMT)
Dkim-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=bgs.ac.uk;
s=selector1;
h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck;
bh=HcowbKDlMSbuRnqmvP7S5vjRPN1mkXItRRUW9zDlles=;
b=F0CTsHbjijr6Uo7pReM16gbvILJt1zIumGU+GJYsv+12WUUY5IS3kOtxf9g2PT6vJmpeZMXIYHCjjlUI9kpomLDH1bSx+X/powMQuxNzQIiyaT6dKHoa1ttO2RBQHwbc1kf8QneQOwdtJHKLNdUN9/LtaBSgiKWB4p3WHgvtP/0=
Received: from LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM (20.176.158.11) by
LO2P123MB2304.GBRP123.PROD.OUTLOOK.COM (20.176.155.148) with Microsoft SMTP
Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id
15.20.1643.20; Wed, 27 Feb 2019 13:29:13 +0000
Received: from LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM
([fe80::bcee:c4aa:6aef:b1cb]) by LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM
([fe80::bcee:c4aa:6aef:b1cb%3]) with mapi id 15.20.1643.019; Wed, 27 Feb 2019
13:29:13 +0000
SEISMIC ALERT: NEWDIGATE, SURREY 27 FEBRUARY 2019 03:42 UTC 3.1 ML
The following preliminary information is available for this earthquake:
DATE : 27 February 2019
ORIGIN TIME : 03:42 21.3s UTC
LAT/LONG : 51.164? North / 0.246? West
GRID REF : 522.6 kmE / 142.1 kmN
DEPTH : 2.3 km
MAGNITUDE : 3.1 ML
LOCALITY : Newdigate, Surrey
2019 227 0342 21.3sL 51.164 -0.246 2.3 BGS 11 0.1 3.1LBGS 1
GAP=112 0.29 0.5 0.9 1.2 0.5694E-02 -0.2199E+00 0.8035E-01E
ACTION:REE 19-02-27 05:49 OP:gdf STATUS: ID:20190227034223 I
2019-02-27-0342-18S.GB____202 6
2019-02-27-0340-51S.Regio_352 6
XNEAR 10.0 XFAR 50.0 SDEP 1.0 3
NEWDIGATE,SURREY 4 23
FELT SURREY... 3
4 0.00 0.00 0.0 2
STAT SP IPHASW D HRMM SECON CODA AMPLIT PERI AZIMU VELO SNR AR TRES W DIS CAZ7
STAN HZ IP C 342 22.10 155 -0.0310 0.68 340
STAN HN ES 342 22.79 155 0.0510 0.68 340
STAN HE IAML 342 23.14 30.3e4 0.25 0.68 340
STAN HN IAML 342 23.17 24.9e4 0.24 0.68 340
RUSH HZ IP C 342 22.26 110 -0.1010 2.39 221
RUSH HE ES 342 23.02 110 -0.1210 2.39 221
RUSH HN IAML 342 23.21 15.0e4 0.14 2.39 221
RUSH HE IAML 342 23.46 16.3e4 0.22 2.39 221
GATW HZ IP D 342 22.62 105 0.1710 2.77 141
GATW HN ES 342 23.41 105 0.1210 2.77 141
GATW HN IAML 342 23.56 19.5e4 0.13 2.77 141
GATW HE IAML 342 23.65 16.4e4 0.25 2.77 141
HORS HZ IP C 342 22.39 104 -0.0910 2.88 63
HORS HE ES 342 23.18 104 -0.1610 2.88 63
HORS HN IAML 342 23.40 17.3e4 0.13 2.88 63
HORS HE IAML 342 23.42 17.4e4 0.14 2.88 63
BRDL HZ IP D 342 22.51 103 0.0110 3.00 333
BRDL HN ES 342 23.52 103 0.1410 3.00 333
BRDL HE IAML 342 23.73 29.8e4 0.22 3.00 333
BRDL HN IAML 342 23.74 24.3e4 0.23 3.00 333
HMNX HZ EP 342 31.13 51 -0.03 0 52.5 129
HMNX HN ES 342 41.31 51 2.95 0 52.5 129
HMNX HN IAML 342 48.36 1272.2 0.48 52.5 129
HMNX HE IAML 342 50.61 1909.8 0.42 52.5 129
ELSH HZ IP D 342 38.95 51 0.86 0 96.6 91
ELSH HN ES 342 52.88 51 2.53 0 96.6 91
ELSH HN IAML 343 1.43 329.9 0.36 96.6 91
ELSH HE IAML 343 2.87 558.9 0.64 96.6 91
SWN1 HZ EP 342 41.76 51 0.75 0 115 290
SWN1 HN ES 342 57.62 51 2.22 0 115 290
SWN1 HN IAML 343 0.29 538.0 0.58 115 290
SWN1 HE IAML 343 8.87 340.0 0.52 115 290
ELMS HZ EP 342 44.93 46 1.13 0 134 39
ELMS HE ES 343 2.15 46 1.92 0 134 39
ELMS HN IAML 343 4.49 704.2 0.37 134 39
ELMS HE IAML 343 5.34 506.6 0.43 134 39
WACR HZ EP 342 52.11 39 1.49 0 184 19
WACR HN IAML 343 16.68 338.6 0.28 184 19
WACR HE IAML 343 18.83 417.0 0.30 184 19
MCH1 HZ EP 342 54.79 39 0.55 0 212 297
MCH1 HN IAML 343 25.63 160.3 0.42 212 297
MCH1 HE IAML 343 25.91 126.6 0.61 212 297
This email and any attachments are intended solely for the use of the named recipients. If you are not the intended recipient you must not use, disclose, copy or distribute this email or any of its attachments and should notify the sender immediately and delete this email from your system.
UK Research and Innovation has taken every reasonable precaution to minimise risk of this email or any attachments containing viruses or malware but the recipient should carry out its own virus and malware checks before opening the attachments. UK Research and Innovation does not accept any liability for any losses or damages which the recipient may sustain due to presence of any viruses.
Opinions, conclusions or other information in this message and attachments that are not related directly to UK Research and Innovation business are solely those of the author and do not represent the views of UK Research and Innovation.