Data Report
Alert /
Contributed by BGS
Return-Path:
X-Original-To: seismo@isc.ac.uk
Delivered-To: seismo@isc.ac.uk
Received: from GBR01-CWL-obe.outbound.protection.outlook.com (mail-eopbgr110092.outbound.protection.outlook.com [40.107.11.92])
by www.gxjydl.com (Postfix) with ESMTP id 2FAC0613C0
for ; Tue, 23 Apr 2019 14:55:03 +0100 (BST)
Dkim-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=bgs.ac.uk;
s=selector1;
h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck;
bh=hN8WwcfXcrzYMPVyNjzJF8b/ydagQRBQJiVXSShbNiE=;
b=EcGDbt7BPrjSDS1HFBV8pMOPTcCZEWblOOUqakZYw7zWicWBTBEpDvgK1UqdDGcafZc2Ht1Pt5fFFeYixB05tiFRYv1KqGg+ZobGQaJNWbMwE+71qwjeS8KwCp4Hf2ffzzAH11S9i4z/pclqhuzFCmGX0eC38kpo3CnMKwQ4E80=
Received: from LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM (20.176.158.11) by
LO2P123MB2064.GBRP123.PROD.OUTLOOK.COM (20.176.155.18) with Microsoft SMTP
Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id
15.20.1813.17; Tue, 23 Apr 2019 13:54:46 +0000
Received: from LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM
([fe80::95a0:ac7e:4e7:24c]) by LO2P123MB2399.GBRP123.PROD.OUTLOOK.COM
([fe80::95a0:ac7e:4e7:24c%7]) with mapi id 15.20.1813.017; Tue, 23 Apr 2019
13:54:46 +0000
The following preliminary information is available for this event:
DATE:23 April 2019
ORIGIN TIME:12:32 03.2s UTC
LAT/LONG:49.419? North / 0.402? West
GRID REF:515.9 kmE / -52.2 kmN
DEPTH:0 km
MAGNITUDE:2.3 ML
LOCALITY:English Channel (approx. 140 km SSE of Ventnor, IOW & 25 km NW of Bayeux, Calvados, France)
2019 423 1232 3.24Lf 49.419 -0.402 0.0 BGS 18 0.4 2.3LBGS 1
GAP=212 0.86 5.4 8.6 0.0 -0.3723E+02 0.0000E+00 0.0000E+00E
2019-04-23-1231-23S.OLD___097 6
2019-04-23-1232-00S.EXT___071 6
2019-04-23-1232-00S.EWA___305 6
ACTION:REE 19-04-23 13:27 OP:dag STATUS: ID:20190423123123 I
XNEAR 500.0 XFAR 1000.0 SDEP 15.0 3
ENGLISH CHANNEL 23
140KM SSE VENTNOR 3
STAT SP IPHASW D HRMM SECON CODA AMPLIT PERI AZIMU VELO SNR AR TRES W DIS CAZ7
JDG EZ EP 1232 23.84 38 0.0210 122 259
JDG EE IAML 1232 44.61 26.1 0.20 122 259
JDG EN IAML 1232 44.90 26.7 0.46 122 259
JDC EZ EP 1232 24.16 38 0.3310 122 259
JDC EE IAML 1232 43.34 172.5 0.18 122 259
JDC EN IAML 1232 46.01 141.7 0.19 122 259
JRS EN IAML 1232 44.33 50.9 0.22 125 259
JRS EE IAML 1232 45.30 44.6 0.18 125 259
JLP EZ EP 1232 24.34 38 0.0410 125 262
JRS EZ EP 1232 24.28 38 -0.0610 125 259
JSA HZ EP 1232 25.23 38 0.0010 131 259
JSA HN IAML 1232 45.50 34.3 0.42 131 259
JSA HE IAML 1232 46.59 26.8 0.22 131 259
HMNX HZ EP 1232 31.60 35 0.8710 169 18
HMNX HE IAML 1232 56.16 102.2 0.62 169 18
HMNX HN IAML 1232 58.87 119.0 0.46 169 18
ELSH HZ EP 1232 36.73 30 -0.5910 221 29
ROSF BZ EP 1232 39.89 30 -0.1210 243 241
SWN1 HZ EP 1232 41.70 30 0.3810 253 337
DYA HZ EP 1232 43.98 30 -0.3910 277 295
DYA HN IAML 1233 27.78 15.3 0.40 277 295
DYA HE IAML 1233 32.47 10.5 0.26 277 295
STRD HZ EP 1232 46.21 30 0.2510 290 335
STRD HE IAML 1232 46.89 32.0 0.38 290 335
STRD HN IAML 1232 46.90 45.0 0.34 290 335
MONM HZ EP 1232 49.45 30 0.0010 318 329
MONM HN IAML 1233 44.60 12.0 0.40 318 329
MONM HE IAML 1233 46.04 8.3 0.42 318 329
SBD BZ EP 1232 51.00 30 -0.2410 333 294
MCH1 HZ EP 1232 51.83 30 -0.4010 340 328
MCH1 HN IAML 1233 31.39 6.1 0.20 340 328
MCH1 HE IAML 1233 52.61 7.3 0.46 340 328
HTL HZ EP 1232 52.61 30 0.4610 340 303
HTL HN IAML 1233 47.49 11.8 0.48 340 303
HTL HE IAML 1233 49.84 8.7 0.54 340 303
CCA1 HZ EP 1232 54.65 30 0.2610 358 286
CCA1 HN IAML 1233 36.04 5.0 0.50 358 286
CCA1 HE IAML 1233 49.81 4.2 0.64 358 286
HLM1 HZ EP 1232 57.51 30 -0.4910 386 334
HLM1 HE IAML 1233 14.37 5.3 0.44 386 334
HLM1 HN IAML 1233 14.68 4.8 0.34 386 334
WPS HZ EP 1233 15.13 30 -0.33 9 527 329
This email and any attachments are intended solely for the use of the named recipients. If you are not the intended recipient you must not use, disclose, copy or distribute this email or any of its attachments and should notify the sender immediately and delete this email from your system.
UK Research and Innovation has taken every reasonable precaution to minimise risk of this email or any attachments containing viruses or malware but the recipient should carry out its own virus and malware checks before opening the attachments. UK Research and Innovation does not accept any liability for any losses or damages which the recipient may sustain due to presence of any viruses.
Opinions, conclusions or other information in this message and attachments that are not related directly to UK Research and Innovation business are solely those of the author and do not represent the views of UK Research and Innovation.